← All terms

Glossary · Energy industry & energy transition

Island grid

An island grid is a power grid or a delimited grid section that is operated without an electrical connection to a larger interconnected grid. Within its boundaries it must cover the demand for electrical energy, balance the instantaneous power balance, and keep voltage and frequency stable. Some island grids exist permanently, for example on geographical islands, in remote regions or at industrial sites without a grid connection. Others arise only temporarily: when a grid section separates from the interconnected grid during a disturbance, or when a local grid is deliberately kept in operation without a connection to the outside.

The term says nothing about the size of the grid. An island grid can be a small site grid, a municipal sub-grid, an industrial grid or the power system of an entire island. The only decisive point is that there is no coupling to a superordinate synchronous grid. This fundamentally changes the operating conditions. In the interconnected grid, fluctuations in generation and consumption are balanced out across a very large number of power plants, consumers, storage units and lines. In an island grid, only its own installations and equipment are available for this purpose.

The most important technical requirement is a constant balance of electrical power. The grid itself can store energy only to a very small extent, for example in rotating masses or in electric and magnetic fields. The active power fed in must therefore essentially equal consumption plus grid losses at every point in time. If there is too little generation, the frequency falls. If there is too much, it rises. In the European interconnected systems the nominal frequency is 50 hertz. An island grid does not have this grid frequency imposed from outside but must lead it itself. Depending on the control concept, it may fluctuate within defined limits.

Voltage, too, must remain within permissible limits. For this purpose, reactive power is provided or absorbed. Voltage control is particularly difficult when the grid is sparsely meshed, has long lines or absorbs a lot of fluctuating feed-in from photovoltaics and wind power. In the large interconnected system, these tasks are distributed across many grid levels and items of equipment. In an island grid they must be solved locally, usually with significantly less reserve.

The term in the European network code

The European network code for requirements for grid connection of generators (Regulation (EU) 2016/631, Article 2(43)) does not define the island grid itself but island operation. This means the independent operation of a whole network or part of a network that is isolated after being disconnected from the interconnected system. At least one power-generating module or an HVDC system must supply the network and control its frequency and voltage. This definition makes clear what matters: a separated part of a network becomes a functioning island grid only when a facility takes over leading the frequency and voltage. Larger generating facilities must, under this regulation, be able to participate in island operation if the competent network operator requires this in coordination with the transmission system operator. Which types of facilities are affected and which thresholds apply follows from the regulation and its national implementations.

Distinction from emergency power, self-sufficiency and microgrids

Island grids are often equated with emergency power supply. This is imprecise. An emergency power system usually supplies only selected consumers for a limited time, for example safety lighting, data centres, hospitals or pumps. It does not necessarily form a full-fledged power grid with controlled frequency and voltage, protection technology, load management and coordinated feed-in from several installations. An island grid may include emergency power functions but goes technically beyond them.

Self-sufficiency does not mean the same thing either. Self-sufficiency describes the goal of covering energy or electricity demand, on paper or in practice, from one's own sources. A building with photovoltaics and a battery storage system can achieve a high degree of self-supply over the year and is still not a stably operated island grid. Island operation requires a control system that maintains voltage and frequency at every load change and every fluctuation in generation. The annual balance says little about whether the grid remains stable on a windless winter night or during a sudden load step.

The term microgrid overlaps with the island grid but is likewise not synonymous. A microgrid is a locally delimited power system consisting of generators, consumers, control and often storage. It can run on the public grid and switch to island operation when needed. In short: island grid and island operation describe an operating state without a connection to the interconnected grid, whereas a microgrid describes rather the technical and organisational unit.

Furthermore, a distinction must be made between planned and unintentional island operation. In public distribution grids, uncontrolled islanding is generally to be prevented. It can endanger people, disrupt protection concepts and damage equipment. If, for example, a photovoltaic system continues to feed in after a grid disconnection even though the grid section should be de-energised, this can be life-threatening for fitters. In Germany, the VDE application rule VDE-AR-N 4105 therefore requires, for generating plants on the low-voltage grid, grid and system protection with island grid detection. This disconnects the plant from the grid via a coupling switch within a few seconds. However, the detection must not undermine the desired grid support during short voltage dips. The plant must therefore reliably distinguish whether it is to ride through a fault and support the grid or whether an undetected island grid exists. The specific time limits and procedures depend on the applicable version of the application rule and on the voltage level.

Why island grids matter in the power system

Island grids clearly show which functions a power grid must fulfil before it makes sense to talk about electricity volumes, prices or generation technologies. A power system is not stable merely because enough kilowatt-hours are generated in the balance. It is stable when power is balanced at all times, frequency is led and voltage is maintained, faults are detected and the protection mechanisms are coordinated with one another. In an island grid these tasks emerge particularly clearly because no support from outside is available.

Permanent island grids often have higher generation costs than connected grids. This is due not only to the technology used but above all to the fact that fluctuations cannot be balanced over a wide area. Reserves must be held locally. Storage, controllable generators and load management must be designed so that they also cover unfavourable situations. At the same time, expanding renewable energy in island grids can be particularly economical if diesel generators or other expensive fuels have so far been used. The main task then shifts from fuel supply to controlling a system with strongly fluctuating feed-in.

Through the energy transition, the term is also gaining importance for the public grid. Conventional power plants with synchronous machines long supplied many stabilising properties, so to speak, as a by-product: rotating mass and thus inertia, short-circuit power, voltage support and a physical coupling to the grid frequency. If electricity is increasingly fed in via power electronics, these properties must be provided deliberately. Island grids are a practical test of whether converter-based plants can not only supply a grid but also lead it.

Grid-forming converters play a key role here. Many conventional inverters operate in a grid-following manner: they align themselves with an existing grid voltage and feed in in step with it. In an island grid this is not enough, because the reference for voltage and frequency must first be generated. Grid-forming converters can supply this reference. In interaction with other installations, they ensure that load changes do not immediately lead to unstable states. Battery storage, hydropower plants, combined heat and power plants and other controllable installations can take on different tasks here.

Frequency, voltage, protection and reserve

How well the frequency can be maintained in an island grid depends strongly on the inertia and the control speed of the installations present. If a power plant suddenly fails in the large interconnected system, the frequency changes. However, many rotating masses and the control reserve cushion this change. In a small island grid, a failure of the same relative size can trigger significantly stronger and faster frequency deviations. Fast control, sufficient reserve and, if necessary, load shedding are therefore needed there.

In load shedding, consumers are deliberately disconnected so that the rest of the grid remains stable. This is not a sign of poor planning but a protective mechanism for the case that all other reserves are not sufficient. In well-designed island grids, the shedding stages are defined in advance. Critical consumers remain supplied as long as possible, while less important loads are switched off first. The topic of island grids thus also touches on questions of prioritisation and responsibility: who decides which consumers continue to receive power in a disturbance, and according to what rules?

Protection technology must also be considered differently than in the interconnected grid. Protection devices often detect faults by high short-circuit currents. Converters, however, usually limit their current to values close to their rated current. In grids with many converters, fault currents can therefore turn out significantly lower or behave differently than with synchronous machines. A protection concept that works in the interconnected grid is therefore not automatically suitable for island operation. Safe operation requires coordinated protection settings, often different parameter sets for grid-parallel and island operation, as well as communication concepts and clear operating specifications.

Island grid, black start and resilience

Island grids also play a role in restoration after a large-scale blackout. Black start capability refers to the ability of a facility to start up without an external power supply and to re-energise a grid. Around such facilities, small electrical islands initially form. They supply selected consumers, take on further generators and are later synchronised and interconnected. For the EU, the network code on electricity emergency and restoration (Regulation (EU) 2017/2196) governs this process. Transmission system operators must draw up restoration plans. These provide for providers with black start capability or the capability for island operation, as well as procedures for resynchronising parts of the network in island operation. Excluded are the networks of islands of Member States that are permanently not operated synchronously with one of the European synchronous areas, provided this state did not arise from a disturbance.

Individual black-start-capable facilities are not sufficient for restoration. Also needed are technically suitable grid sections, clear operating procedures, functioning communication, trained personnel and loads that can be connected in suitable steps. Under the network code, transmission system operators can, during restoration, require selected distribution system operators to provide information on which parts of the network are in island operation, whether these can be synchronised and whether island operation can be started there. In this context, an island grid is therefore not an improvised residual operation but a planned operating state with its own rules.

The term is also important for the resilience of critical infrastructure. Hospitals, waterworks, telecommunications, control centres and industrial processes cannot be secured by a calculated electricity balance alone. They need a supply that continues to run stably when disconnected from the public grid or is restored in a controlled manner. Whether a full-fledged island grid, an emergency power supply or a hybrid concept is needed for this depends, among other things, on load profile, outage tolerance, fuel availability, storage size and control technology.

Typical misinterpretations

  • Island grid as a simple solution to grid problems: Local generation and storage can reduce dependence on the interconnected grid but do not automatically take over its functions. A midday surplus of photovoltaic power helps little if load is high in the evening and not enough controllable power or storage capacity is available. What matters is not the annual amount generated but the time profile of generation, consumption and reserves.

  • Island grid as complete independence: Even a technically self-sufficient island grid depends on equipment, maintenance, spare parts, fuels, communication systems and qualified personnel. With battery storage, ageing, state of charge and power electronics come into play; with diesel generators, fuel logistics and emissions. With renewable sources, weather and seasons determine the design. Island operation thus reduces certain dependencies and creates others in return.

  • Island grid as the opposite model to the interconnected grid: Often the benefit lies precisely in the combination. A grid section can be connected to the interconnected grid in normal operation, use its balancing effects and switch in a controlled manner to island operation during disturbances. This requires switching technology, synchronisation, control concepts and clear responsibilities among plant operators, network operators and, where applicable, operators of critical facilities.

Conclusion

The island grid makes visible which tasks a power grid must fulfil when support from the interconnected system is missing. The term does not simply mean a place without a line to the outside. It describes an operating state in which frequency control, voltage control, reserve planning, protection technology and responsibility for the power balance lie entirely on site. Whoever uses the term precisely distinguishes between electrical self-supply and stable grid control. Local generation becomes a resilient island operation only through suitable control, storage, protection concepts and operating rules.