Glossary · Energy industry & energy transition
Installed capacity
Concept and unit
Installed capacity refers to the technical rated power of a plant or a fleet of plants. It indicates what electrical power a plant can continuously supply or absorb under defined conditions. This applies to power plants, wind farms, photovoltaic systems, battery storage systems, electrolysers and large consumption facilities. It is usually expressed in kilowatts, megawatts or gigawatts. Installed capacity is not necessarily the highest instantaneous value ever measured. For short periods, a plant may deliver somewhat more or less. What is meant is the power for which it is designed in continuous operation as intended.
The unit describes an instantaneous capability. A megawatt is a power, not a quantity of energy. Energy arises only over time: if a plant feeds in at one megawatt for one hour, it generates one megawatt-hour of electricity. Installed capacity must therefore be distinguished from electricity consumption, annual generation and final energy. A photovoltaic system of ten kilowatts does not continuously generate ten kilowatts. Its actual feed-in depends, among other things, on solar irradiation, season, orientation, temperature and shading, as well as on the inverter sizing and the grid connection conditions. For wind energy, it depends on wind availability, the power curve of the turbine, shutdowns and local grid bottlenecks.
Legal definition in Germany
For installations under the Renewable Energy Sources Act (EEG), there is a statutory definition. Under Section 3 No. 31 EEG 2023, installed capacity is the electrical active power that an installation can technically deliver in operation as intended without temporal restrictions. Short-term minor deviations are disregarded. This definition applies within the meaning of the EEG, that is, to installations generating electricity from renewable energies and from mine gas. Other regulations, statistics or grid connection conditions may use their own capacity concepts. The special rule for solar installations should also be noted: under Section 3 No. 1 EEG 2023, each individual module is deemed a separate installation. The installed capacity of a PV system is therefore usually determined in the EEG context by the module capacity.
The EEG also recognises the rated average power (Bemessungsleistung). For this, the quantity of electricity generated in a calendar year is divided by the full hours of that year in which the installation was in operation. The rated average power is thus an average power. For almost all installations it is clearly below the installed capacity. An example: an installation with 1,000 kilowatts of installed capacity generates 2,190 megawatt-hours in a full year. Its rated average power is then around 250 kilowatts. This corresponds to a capacity factor of about 25 percent.
Disclosing the reference value: photovoltaics, power plants, storage
The term is precise only if the reference value is disclosed. For photovoltaics, the figure can refer to the direct-current capacity of the modules, stated in kilowatt peak (kWp) under standardised test conditions. It can also refer to the alternating-current capacity at the inverter. The two values often differ because modules and inverters are sized differently. In the German Core Energy Market Data Register (Marktstammdatenregister), the following applies to PV systems: the gross capacity corresponds to the module capacity. The net rated capacity is the smaller of the module and inverter capacities. The earlier short formula, that net capacity is simply the inverter capacity, is therefore imprecise. A register entry can show, for example, 9.9 kWp gross capacity, 9 kilowatts net rated capacity and 9 kilowatts inverter capacity. In addition, a limitation of feed-in power to 70 percent may be recorded. In that case there are three different capacity figures for the same installation.
For conventional power plants, a distinction must be made between gross capacity and net capacity. Gross capacity describes the generator output. Net capacity is the power that can actually be delivered to the grid after deducting the plant's own consumption. For battery storage, a further distinction applies. Installed capacity shows how fast the storage can charge or discharge. The storage capacity in kilowatt-hours or megawatt-hours shows how long it can sustain this power.
Distinction from generation and firm capacity
Installed capacity is often confused with actual generation. This leads to wrong comparisons between technologies. One gigawatt of photovoltaics, one gigawatt of wind energy and one gigawatt of gas-fired power plants are equal in size as rated capacity. However, they deliver very different annual quantities and contribute differently in scarcity situations. For annual generation, full-load hours are an important complement. They indicate for how many hours a plant would theoretically have to run at full power to reach its actual annual generation. Low full-load hours do not automatically mean that a plant is uneconomic or technically inferior. The value depends on function, location, market environment and mode of operation. A peaking power plant, for example, is deliberately designed for few operating hours.
Likewise, installed capacity must not be equated with firm capacity. Firm capacity describes which part of a plant or a fleet of plants is available with a certain probability in times of high load. For weather-dependent generation, this share is clearly smaller than the installed capacity, because sun and wind are not available on demand. Even for thermal power plants it is not one hundred percent. Maintenance, fuel availability, technical faults and operational restrictions must be taken into account. The capacity value describes this contribution to the system better than rated power alone.
Significance for planning and the grid
Despite these limits, installed capacity is a central planning parameter. It determines what connection capacity a plant requires. Cables, transformers, inverters and protection systems are dimensioned according to it, and it shows which maximum feed-in or withdrawal powers can occur in the grid. For grid operators, not only the annual quantity of electricity matters, but also how many installations can feed in or draw electricity at the same time. If many photovoltaic systems are installed in a distribution grid, high feed-in power can occur on sunny days, even if each individual installation generates only a limited amount of energy over the year. Conversely, heat pumps, charging points for electric vehicles or electrolysers can cause high withdrawal powers, although their annual consumption varies greatly depending on use. Power limitations or contractually agreed feed-in limits at the grid connection can also mean that the power actually usable is below the installed capacity.
Installed capacity as a political target value
In expansion planning, installed capacity often serves as a political target value. Section 4 of the EEG 2023 sets an expansion path for photovoltaics in gigawatts: 172 gigawatts in 2028, 215 gigawatts in 2030, 309 gigawatts in 2035 and 400 gigawatts in 2040. According to the German Solar Industry Association (Bundesverband Solarwirtschaft), the mark of 128 gigawatts peak was exceeded in August 2026, thereby reaching the interim target for 2026. Targets are formulated in gigawatts because this quantity is easy to measure and is directly linked to permitting, investment, tendering and grid connection. For the supply situation, however, this figure alone is not sufficient. Installed capacity implies no particular quantity of electricity, no particular time of feed-in and no particular contribution to security of supply. For that, generation profiles, load profiles, storage, dispatchable power plants, grids, import options and flexible demand must be considered together.
Typical fallacies in both directions
A common misunderstanding arises when installed capacity is equated with power plant capacity in the old sense. In a predominantly thermal power plant system, one megawatt of plant capacity was closer to schedulable generation, even though outages and maintenance had to be taken into account. In an electricity system with a high share of photovoltaics and wind energy, technical rated power departs further from controllable availability. More renewable capacity increases possible generation and in many hours reduces the need for fuel-fired power plants. But it does not automatically replace the same amount of dispatchable capacity for periods of low wind and sun (Dunkelflauten), grid reserve or peak load.
The opposite shortcut is also problematic. From the lower capacity value of weather-dependent generation it does not follow that its installed capacity is worthless. It determines how much cheap electricity is generated in many hours. It reduces fuel consumption and emissions, changes wholesale prices and creates new requirements for flexibility. The value of a plant does not arise from rated power alone. It results from generation profile, location, grid connection, market prices, support rules and the needs of the system. An additional photovoltaic system in an already heavily loaded low-voltage grid has a different effect from the same system at a grid connection point with free absorption capacity. A wind farm at a very good site can be more valuable despite higher grid connection costs than a plant at a weak site with a simple connection.
Storage: same capacity, different tasks
For storage, the limits of the concept are particularly evident. A battery storage system with 100 megawatts of power and 100 megawatt-hours of capacity can discharge at full power for one hour. A storage system with the same power and 400 megawatt-hours of capacity can do so for four hours. Both have the same installed capacity but fulfil different tasks. Frequency regulation, short-term load shifting, congestion management and the safeguarding of longer scarcity periods each require different combinations of power, energy content, response speed and operating strategy.
Economic and institutional context
Economically, installed capacity acts through investment costs, revenue models and grid charges. Many costs depend on capacity: turbines, generators, inverters, transformers and grid connections must be dimensioned for peak power. Revenues, by contrast, arise from the sale of energy, the provision of flexibility, avoided grid charges, support payments or system services. High installed capacity can therefore cause high fixed costs without high revenues automatically following. For weather-dependent installations, the market value additionally depends on how many similar installations feed in at the same time. If a great deal of photovoltaics generates electricity simultaneously, prices fall more often in those hours. The rated power stays the same, but its economic value changes through simultaneity in the market.
Institutionally, installed capacity touches several areas of responsibility. Permitting authorities examine the site, land, environmental impacts and technical documents. Grid operators examine connection requests, grid compatibility and possible grid reinforcements. Market participants calculate revenues and risks. Politics and administration use the figure for expansion targets, tenders and monitoring. In Germany, capacity data are recorded in the Marktstammdatenregister of the Bundesnetzagentur (Federal Network Agency). A reported installed capacity, however, does not say whether the installation will be connected in time, whether it may feed in at all times or whether its electricity can be consumed at the desired location.
Conclusion
Installed capacity is a necessary but incomplete measure. It describes how large a plant is technically dimensioned, and for this it needs a clear reference value: module or inverter capacity, gross or net. It does not explain how much electricity a plant delivers per year, when it feeds in or draws electricity, or how reliably it is available in scarcity situations. Nor does it show what economic value the plant has in its respective grid and market environment. For robust statements about the electricity system, it must be read together with energy generation, load profile, full-load hours, capacity value, grid connection and flexibility.
Sources
- Gesetz für den Ausbau erneuerbarer Energien (EEG 2023), § 3 Begriffsbestimmungen — Bundesministerium der Justiz / Bundesamt für Justiz (gesetze-im-internet.de); unbekannt (konsolidierte Fassung, abgerufen am 28.11.2026). § 3 Nr. 1, Nr. 6 und Nr. 31 EEG 2023
- Erneuerbare-Energien-Gesetz (EEG 2023), Gesamtausgabe als PDF — Bundesministerium der Justiz / Bundesamt für Justiz (gesetze-im-internet.de); unbekannt. § 4 EEG 2023 (Ausbaupfad Solarenergie), laut Suchergebnis-Auszug
- Marktstammdatenregister – Definitionen und Datendefinition (Vortrag) — Bundesnetzagentur; 2016-09-27. Folien „Leistungsbegriffe bei der Stromerzeugung“ und „Datendefinition“
- Marktstammdatenregister – Einheitendetail einer Solareinheit (SEE972143260699) — Bundesnetzagentur (Marktstammdatenregister); 2020-06-24 (Stand des Registerauszugs). Abschnitt „Leistung“ und „Angaben zur EEG-Anlage“
- Solarleistung erreicht 128 GWp – EEG-Ziel für 2026 erfüllt — Solarserver (nach Angaben des BSW-Solar); 2026-08-20. Haupttext
Related glossary entries
- kilowatts, megawatts or gigawatts
- capacity factor
- gross capacity and net capacity
- storage capacity
- full-load hours
- firm capacity
- capacity value
- security of supply
- flexibility