Glossary · Energy industry & energy transition
IEC 62443
IEC 62443 is an international series of standards on the cybersecurity of industrial automation and control systems. It is developed by the IEC together with the ISA99 committee of the International Society of Automation. It covers systems that monitor, control or safeguard technical processes. In the power system, these include, for example, network control systems, protection and control devices in substations, power plant control systems, industrial controllers, telecontrol systems and the plant controllers of storage systems and generation plants. The series therefore mainly concerns operational technology, in short OT, as opposed to classic office IT. It was originally intended for industrial automation. It is now also used in the energy sector because it offers a method for implementing security in cyber-physical operational and field environments.
The series of standards does not describe a single technical measure. It provides a model of roles, processes, security requirements and system architectures that covers organisational and technical aspects across the entire lifecycle. It is addressed to operators, system integrators, manufacturers and service providers. This division matters because industrial cybersecurity rarely arises at a single point. A network operator can introduce secure operating processes but remains dependent on the properties of the components used. A manufacturer can develop secure products but does not know every later plant architecture. An integrator assembles components into a working system. In doing so, it creates interfaces, permissions and communication paths that become relevant for security.
The central term is Industrial Automation and Control Systems, IACS for short. IEC/TS 62443-1-1 deliberately defines it broadly. In addition to controllers in manufacturing and process plants, it expressly includes geographically distributed infrastructures such as electricity, gas and water supply. An IACS includes not only programmable logic controllers, protection devices or operator interfaces. It also includes servers, engineering stations, network technology, remote maintenance access points, protocol converters and the communication relationships between them. The term is therefore broader than individual control systems, but narrower than general enterprise IT. It describes the area in which digital systems act directly on physical processes.
Structure of the series of standards
The parts of the series are organised into four groups. The most important documents and their main addressees are:
-
Part 1 (General): IEC/TS 62443-1-1 defines terms, concepts and models, including the seven foundational requirements (Foundational Requirements).
-
Part 2 (Policies and procedures): IEC 62443-2-1 governs the security program of the asset owner, which here also includes the operator. The second edition was published in August 2024. It structures the requirements into program elements, avoids duplication with an information security management system and introduces a maturity model. IEC TR 62443-2-3 addresses patch management, and IEC 62443-2-4 covers requirements for service providers in integration and maintenance.
-
Part 3 (System): IEC 62443-3-2 describes risk assessment, the division into zones and conduits, and the definition of target security levels. IEC 62443-3-3 contains the technical system requirements and the security levels.
-
Part 4 (Components): IEC 62443-4-1 defines a secure development lifecycle for manufacturers. IEC 62443-4-2 contains technical requirements for embedded devices, network components, host components and software applications. They are derived from the system requirements of Part 3-3.
Zones, conduits and security levels
A core element is the division of a plant into zones and conduits. A zone groups systems with comparable risk and protection needs. A conduit is the controlled communication link between zones. In a substation, for example, one zone may consist of protection and control devices, a second of the station operator interface and a third of the telecontrol links to the network control system. Between these zones there are defined communication paths with their own rules, such as protocol filtering, authentication, logging or restricted remote access. Under IEC 62443-3-2, a detailed risk assessment is carried out for each zone and each conduit, and a target security level (SL-T) is defined.
This way of thinking goes beyond looking at products alone. A component may have robust security functions and still run in an insecure architecture. Conversely, an older component without modern cryptography can be kept in operation in a tightly delimited zone with controlled connections, provided that risk, importance to the process and protective measures have been carefully assessed. The standard expressly provides for compensating countermeasures for this purpose. This particularly concerns existing plants whose devices technically do not support certain functions. IEC 62443-2-1 assumes that an IACS can be in use for more than twenty years. The series thus forces an architectural view: Which systems may communicate with each other? Which functions are operationally necessary? Which paths could an attacker use? And what would be the consequences of a failure or manipulation?
The technical requirements are assigned to seven foundational requirements: identification and authentication control (FR1), use control (FR2), system integrity (FR3), data confidentiality (FR4), restricted data flow (FR5), timely response to events (FR6) and resource availability (FR7). For each foundational requirement there are specific system requirements and enhancements assigned to the four security levels SL 1 to SL 4. The levels describe against which attacker capability protection is provided. They range from protection against casual or coincidental violations to protection against targeted attacks using sophisticated means, extensive resources and expert knowledge of control systems. A distinction is made between the target level (SL-T), the capability of a system or product (SL-C) and the level actually achieved (SL-A).
A security level is not a blanket quality class and only makes sense in the context of the risk assessment. For a zone or conduit, it is strictly speaking a vector with seven values, one per foundational requirement. If, for example, confidentiality plays hardly any role in a protected zone, FR4 can be set low, while integrity and access control are rated high. For control systems in the power grid, this is typical, since manipulation and failure often weigh more heavily there than the reading of measured values by third parties. A local operator device in an isolated zone can therefore have a different target level than a central remote maintenance access point or the link between the network control centre and the substation. The aim is not to reach the highest level everywhere. What matters is which level a particular function requires, measured against its exposure and the possible consequences of damage.
Distinction from ISO/IEC 27001, IEC 62351, law and certificates
IEC 62443 is often confused with general information security standards. ISO/IEC 27001 describes an information security management system (ISMS) for an entire organisation. It governs how risks are systematically identified, responsibilities defined, measures monitored and improvements organised. IEC 62443 is closer to plants, control systems and technical architectures. The two approaches complement each other. For the energy sector, the IEC expressly mentions the combination with the ISO/IEC 27000 series, especially ISO/IEC 27019. The 2024 edition of IEC 62443-2-1 was deliberately revised so that it does not duplicate an existing ISMS. In addition there is IEC 62351. This series provides concrete security mechanisms for communication protocols in power engineering, while IEC 62443 sets the methodological framework.
Legal requirements are likewise not the same as IEC 62443. In Germany, the act implementing the NIS2 Directive entered into force on 6 December 2025 and also amended the Energy Industry Act (Energiewirtschaftsgesetz). For operators of energy supply networks, as well as for energy installations and digital energy services that qualify as important or particularly important entities, the Federal Network Agency (Bundesnetzagentur), in agreement with the BSI, sets the requirements in an IT security catalogue under § 5c EnWG. Until a new catalogue is published, the old catalogues continue to apply to the previous addressees: the one for electricity and gas networks dated August 2015 and the one for energy installations dated December 2018. According to the Federal Network Agency, the planned new catalogue is to be oriented more closely to the management system approach of ISO/IEC 27001. According to the sources reviewed, IEC 62443 is not a mandatory standard there. However, it can help to specify the required measures for the OT environment in a technically robust way, and it does not replace any statutory obligation.
Another misunderstanding concerns certificates. The IECEE conformity assessment system offers, among other things, certificates for development processes under IEC 62443-4-1, for service provider capabilities under IEC 62443-2-4, and for systems under IEC 62443-3-3 and components under IEC 62443-4-2. However, a certified product does not automatically make a plant secure. The certificate attests defined development processes or security capabilities, that is, an SL-C. How secure a specific plant is depends on parameterisation, network segmentation, user management, logging, patch processes, remote maintenance, backup concepts and emergency procedures. IEC 62443 is therefore not a seal of quality that replaces the operator's responsibility for its system.
Significance in the power system
In the power system, cybersecurity has a special quality because digital attacks can trigger physical effects. A manipulated switching operation, a falsified measured-value transmission or a failed control system is more than a data protection problem. Network operation, plant safety, security of supply and network restoration after disturbances may be affected. Therefore, in addition to confidentiality, integrity and availability above all count. Measured values must be correct, commands must be authorised, protection functions must work reliably, and operating personnel must remain able to act in the event of a disturbance.
With the increasing interconnection of the energy system, the importance grows further. Decentralised generation, controllable consumption devices, battery storage, charging infrastructure, direct marketing, redispatch and digital network management create additional communication relationships. These are operationally useful but can open up new attack paths. IEC 62443 helps to treat such connections as part of technical system design rather than as a subsequent IT problem. Anyone tendering for a plant should define target security levels and requirements for suppliers early on. Otherwise, dependencies arise later on proprietary interfaces, insecure remote maintenance paths or legacy components that cannot be patched.
This also has economic consequences. Security requirements influence procurement, supplier selection, integration effort, commissioning, maintenance windows and lifecycle costs. A seemingly inexpensive controller can become expensive if it does not support role-based user management, if security updates cannot be planned, or if protocols can only be connected via insecure interim solutions. IEC 62443 does not make such costs disappear, but makes them visible earlier. The emphasis thus shifts from retrofitted protection to security-oriented planning.
Typical misinterpretations
A common oversimplification is to treat OT security like classic IT security. In office IT, patches can often be rolled out quickly, end devices replaced or services shut down at short notice. Different conditions apply in industrial plants. Controllers remain in use for a very long time, plants may only be changed in certain time windows, and changes must be tested because a faulty update can disrupt process control. IEC 62443-2-1 also recognises that patch requirements cannot be met when software is no longer supported. Compensating measures are then called for. Security measures must be compatible with operational safety, occupational health and safety, plant availability and technical approvals.
Equating network segmentation with security is equally imprecise. Segmentation is important, but only works if the transitions are controlled, documented and maintained. A firewall rule set for which, after several extensions, nobody is technically responsible any longer may obscure the architecture rather than protect it. The series therefore requires, in addition to technical barriers, a security program with responsibilities, change processes and regular review.
Another error is the assumption that cybersecurity mainly concerns attacks from the internet. In OT environments, risks also arise from maintenance laptops, removable media, service provider access, misconfigurations, unclear user rights, outdated engineering software or undocumented connections between plant areas. The cause often does not lie in a single vulnerability. It lies in the way plants have been extended, modernised and linked to new operational requirements over the years.
Roles and responsibility
IEC 62443 organises security along roles. The asset owner or operator bears ultimate responsibility for secure operation. It assesses risks, defines zones, establishes processes and formulates requirements for suppliers. Under IEC 62443-4-1 and 4-2, manufacturers must demonstrate in a traceable way how they implement security functions, vulnerability management and secure development. Integrators and service providers build from components an architecture that meets the defined protection needs. IEC 62443-2-4 applies to them. Maintenance and remote access service providers become part of the security model as soon as they gain access to systems or information.
For critical infrastructures, this separation of roles is particularly important. A network operator cannot fully outsource security requirements to suppliers, because the consequences of an incident arise in its own network operation. Manufacturers cannot secure every operating environment if operators set up insecure connections or do not disable default accounts. Integrators need clear specifications on protection needs, operating processes and permissible communication relationships. Anyone applying IEC 62443 sensibly therefore does not talk only about conformity with the standard. It is about traceable security objectives, clear zones, controlled connections and robust responsibilities. The aim is to keep critical technical processes manageable even in the event of digital disturbances.
Sources
- IEC 62443 – Cyber Security and Resilience Guidelines for the Smart Energy Operational Environment — IEC System Committee Smart Energy (SyC SE); 2020-03-02 (letzte Änderung laut Seitenmetadaten). Abschnitte Background, General organization, System related parts, IEC 62443-3-3, IECEE
- IEC 62443-2-1:2024 Security for industrial automation and control systems – Part 2-1: Security program requirements for IACS asset owners — International Electrotechnical Commission (IEC); 2024-08-07. Produktbeschreibung/Abstract
- Festlegung IT-Sicherheitskatalog gem. § 5c Abs. 2 EnWG — Bundesnetzagentur; unbekannt (Stand nach 6. Dezember 2025). Hauptteil der Seite
- IEC/TS 62443-1-1 Edition 1.0 2009-07 – Terminology, concepts and models (Vorschau) — IEC (Vorschau über ANSI Webstore); 2009-07. Abschnitt 1 Scope
Related glossary entries
- substations
- telecontrol systems
- OT
- control systems
- IEC 62351
- NIS2
- security of supply
- network operator
Edited by eCMS on 28.11.2026 12:01
© 2026 Erik Schmidt. All rights reserved. Quotations with a link to the source are welcome.