Glossary · Energy industry & energy transition
Cell balancing
Cell balancing refers to the deliberate equalization of differing states of charge of individual cells or of groups of cells connected in parallel that are connected in series within a battery system. The aim is that no single cell reaches its upper or lower permissible voltage limit significantly earlier than the others. Balancing is a function of the battery management system. It does not increase the chemically available capacity, but it ensures that a larger share of it can be used safely.
Why cells drift apart
A battery storage system consists of many cells. To reach the required system voltage, cells or cell groups are connected in series, with lithium-ion cells typically providing a few volts each. The same current flows through all cells of a string. If the cells differ slightly, their states of charge drift apart over time. Causes include manufacturing tolerances in capacity and internal resistance, differing self-discharge, temperature differences within the module, and unequal quiescent currents of the measurement electronics. Cells also do not age at exactly the same rate. Small deviations can therefore accumulate over many cycles and long idle periods.
A comparison with a roped climbing team illustrates this: the group only gets as far as its weakest member can go. During charging, the system must limit or switch off the current as soon as the cell with the highest state of charge reaches its upper voltage limit. During discharging, it is over as soon as the cell with the lowest state of charge reaches the lower limit. Lithium-ion cells can be damaged outside their permissible voltage window. These limits are therefore protective limits, not comfort limits. Cells connected in parallel, by contrast, largely equalize their voltage on their own through the direct connection. Balancing therefore mainly concerns the series-connected levels.
A distinction is needed here: if only the state of charge differs while the cells' capacities are equal, balancing can largely restore the usable range. If a cell actually has less capacity, however, it becomes full and empty faster at the same current. Passive balancing cannot remove this capacity limit. Active balancing can partly compensate for it by redistributing energy during operation.
Measured variables and state estimation
The key variables are cell voltage, capacity in ampere-hours, and state of charge. Cell voltage can be measured directly. The state of charge, by contrast, is determined through a state estimation, namely from current measurement, voltage curve, temperature, and cell models. The EU Battery Regulation defines the state of charge as the available energy expressed as a percentage of the rated capacity declared by the manufacturer. It defines the state of health as a measure of the condition of the battery compared with its condition when new. Balancing algorithms therefore work either on a voltage basis or on the basis of estimated states of charge.
Balancing is particularly demanding with lithium iron phosphate. The voltage curve of this chemistry is very flat over wide ranges of the state of charge. Small differences in state of charge hardly show up there as voltage differences and often become clearly visible only near the upper or lower end. Many systems therefore balance mainly in the upper charging range. A common misunderstanding is that balancing simply means fully charging all cells. In fact, the aim is to deliberately reduce differences between the cells, and to do so within the operating limits set by the manufacturer.
Passive and active balancing
In passive (dissipative) balancing, the system deliberately discharges cells with a higher state of charge through switchable resistors. The excess energy is converted into heat. All cells are thus brought to the level of the cell with the lowest state of charge. The method is simple, robust, and inexpensive, and is frequently used in practice. It usually runs during or after charging. The drawbacks are the energy loss, the additional heat in the module, and a limited balancing speed, because the balancing currents are small relative to the operating current.
In active balancing, energy is moved from cells with a higher state of charge to cells with a lower one instead of being dissipated as heat. Depending on the circuit, this takes place between individual cells, between cell groups, or between modules. In principle there are two approaches: in charge transport via capacitors (charge shuttling), charge is redistributed step by step. The energy-converting approach uses inductors, transformers, or DC-DC converters. Active methods use energy better and balance faster. Their advantages show particularly when the cells' capacities deviate markedly from one another. However, they are more complex and more expensive, and their additional electronics can themselves fail. Which solution is suitable depends on cell chemistry, system size, operating profile, safety concept, and cost.
Distinctions
-
Battery management system: The BMS is the higher-level unit. It monitors voltages, currents, and temperatures, limits charging and discharging power, protects against overcharging and deep discharge, and communicates with the inverter or the system controller. Balancing is a sub-function of it.
-
Cell quality and ageing: Balancing equalizes differences in the state of charge. It cannot repair aged or damaged cells. A declining state of health of individual cells remains and continues to limit the system.
-
Thermal management: Temperature differences accelerate the drifting apart of cells. Good cooling relieves the burden on balancing but does not replace it. Conversely, passive balancing generates heat that must be dissipated.
-
Safety: Balancing is not a protective system against thermal runaway. It is one building block among several, which also include cell monitoring, current limiting, disconnection, and a fire protection concept.
Significance for storage operation and economic viability
Stationary storage systems smooth the feed-in from photovoltaics, shift quantities of electricity between times of day, and provide balancing power. For this, it matters not only how many kilowatt-hours are installed, but also how much of that can be reliably called upon. If the cells drift apart, the usable energy range becomes smaller. The system has to curtail power earlier and switches off more often for protection. For operators, this rarely shows up as a clear defect, but rather as shorter discharge duration, more frequent power limitations, or faster-declining available capacity. The flexibility that a storage system can offer thus also depends on this small-scale function. Manufacturers also often limit the usable charging range to reduce ageing and risks. Balancing operates within these limits.
Legal framework in the EU
The EU Battery Regulation (EU) 2023/1542 does not expressly mention cell balancing as a mandatory function. However, it defines the battery management system as an electronic device that monitors and controls the electrical and thermal functions of a battery in the interest of safety, performance, and lifetime. For stationary battery energy storage systems with a BMS, the Regulation also requires that data for determining the state of ageing and expected lifetime be stored (Article 14 and Annex VII). It also lays down safety requirements for stationary storage systems (Article 12). According to the VDE, these obligations have applied since August 2024. How balancing is technically implemented is governed mainly by product standards, manufacturer specifications, and contracts.
Sources
- Verordnung (EU) 2023/1542 über Batterien und Altbatterien (konsolidierte Fassung) — Europäische Union, EUR-Lex; 2025-07-31 (Konsolidierungsstand). Art. 3 Abs. 1 Nr. 25 (Batteriemanagementsystem), Nr. 27 (Ladezustand), Nr. 28 (Gesundheitszustand); Art. 14; Anhang VII
- VDE Infopapier zur Batterieverordnung (EU) 2023/1542 — VDE; unbekannt. Abschnitt zu Artikel 14 sowie Übersicht der Fristen
- Overview of cell balancing methods for Li-ion battery technology — Wiley, Energy Storage; 2021. Abstract
- Active battery cell balancing methods with variable duration discharge (US-Patent 9209630) — United States Patent and Trademark Office; unbekannt. Description, Stand der Technik
- A Comprehensive Review of Active Cell Balancing and State-of-Charge Estimation Techniques for Lithium-Ion Battery Management Systems in Electric Vehicles — Zenodo; unbekannt (etwa 2026). Description/Abstract
Related glossary entries
- battery management system
- battery storage system
- self-discharge
- state of charge
- state estimation
- lithium iron phosphate
- inverter
- state of health
- thermal runaway
- balancing power
- flexibility
Edited by eCMS on 28.11.2026 12:01
© 2026 Erik Schmidt. All rights reserved. Quotations with a link to the source are welcome.