Glossary · Energy industry & energy transition
Smart metering system (intelligentes Messsystem, iMSys)
In the German electricity system, a smart metering system (intelligentes Messsystem, iMSys) is a digital metering device that is integrated into a communication network via a smart meter gateway. In most cases, this metering device is a modern metering device. Under the statutory definition, it can also be a metering device for registering power measurement. The system must record at least electricity consumption, electricity generation and time of use. In addition, together with the smart meter gateway administrator, it must meet the special requirements for data protection, data security and interoperability. These requirements are laid down in protection profiles and Technical Guidelines. Legally and technically, a smart metering system therefore only comes into being when meter and gateway are combined.
What is measured is electrical energy, usually in kilowatt hours. For billing, balancing and tariff models, however, the energy quantity of a year is increasingly not enough. When electricity is drawn or fed in also matters. A smart metering system can record and transmit values at fine time resolution. The law calls this method meter reading profile measurement (Zählerstandsgangmessung), that is, a series of meter readings determined every quarter of an hour. In this way an annual consumption figure becomes a load profile. To put it illustratively: a kilowatt hour at three o'clock at night means something different for the grid and the market than a kilowatt hour on a cold winter evening with high load.
Distinctions: smart meter, modern metering device, smart grid
The term is often equated with smart meter. This is understandable but imprecise, because in general usage it often refers to any digital electricity meter. German law distinguishes more precisely. A modern metering device displays consumption and time of use. It must be built so that it can be securely connected to a communication network via a smart meter gateway. Without a gateway, however, it is not yet a smart metering system. The law describes the smart meter gateway as a communication unit. It securely connects metering devices and further technical equipment, such as EEG or CHP (KWK) installations. It can also collect, process and send data. The gateway does not decide on electricity prices or grid operation. It provides a certified infrastructure.
Likewise, a smart metering system is not a smart grid. An electricity grid does not become smart merely because digital meters are installed at individual connections. Grid operation requires measurement data, grid models, switching options and clear rules for interventions. In addition, investments in lines, transformers and control technology are needed. The smart metering system can be an interface within this structure. It does not replace grid planning or physical grid capacity.
Measurement, communication and responsibilities
For small customers, consumption used to be read mostly once a year, often from a Ferraris meter. For procurement and balancing, the standard load profile was used. It assumes a typical consumption pattern for entire customer groups. This works as long as households have hardly any controllable loads and their consumption can be planned well statistically. With heat pumps, charging points for electric cars, battery storage, photovoltaic systems and dynamic tariffs, this changes. A household may feed in at midday, charge a car in the evening and have a high electric heating load in winter. A single annual value does not capture such patterns.
Metering point operation is responsible for installation and operation. Under the Metering Point Operation Act (MsbG), the metering point operator is either the default metering point operator (grundzuständiger Messstellenbetreiber) or a third party that takes over this task by contract. As a rule, the default responsibility lies with the operator of the distribution grid. However, the default responsibility can also be transferred to another company. The smart meter gateway administrator is responsible for the technical operation of the gateway. This includes installation, configuration, administration, monitoring and maintenance. A public key infrastructure with digital certificates ensures that communication between the gateway and market participants remains authentic and confidential. The meter is thus part of a regulated data and market infrastructure.
Who gets a smart metering system and what it may cost
A common misconception is that every household must receive a smart metering system. The MsbG does not provide for a nationwide rollout. Default metering point operators must install smart metering systems insofar as this is economically reasonable. This concerns mainly three groups: final consumers with annual consumption above 6,000 kWh, cases with an agreement under § 14a EnWG for a controllable consumption device, and generation installations with more than 7 kW of installed capacity. In the latter two groups, a control device at the grid connection point is in principle added. For up to 6,000 kWh or for installations above 1 up to 7 kW, installation is optional. Since 2025, customers can also request it themselves. Metering points without an obligation for a smart metering system are to be equipped at least with modern metering devices by 2032. The decisive figure is the average of the last three recorded annual consumption values.
Costs are capped. Since 2025, raised price caps under § 30 MsbG apply, which are split between connection users and connection grid operators. For optional installation, the connection user may be charged at most 30 euros gross per year. For consumption above 6,000 up to 10,000 kWh, it is at most 40 euros. Where there is a § 14a agreement or an installation above 7 up to 15 kW, the cap is 50 euros. Higher caps are provided for larger consumption and installations. For installation and operation of a control device, up to 50 euros per year may be charged in addition. If early installation is ordered at the customer's request, an additional charge may apply. The Federal Network Agency (Bundesnetzagentur) may determine deviating price caps by determination.
Distinction from control and energy management
A smart metering system does not automatically save electricity. It measures more precisely and communicates more securely. Savings arise only when people, devices or service providers react to information and price signals. A heat pump does not become more flexible simply because a smart metering system is present. It needs suitable control, a matching tariff or an energy management system for that.
Remote control is also often misclassified. A smart metering system does not mean that arbitrary parties can switch household appliances at any time. For controllable consumption devices under § 14a EnWG, separate rules, determinations of the Bundesnetzagentur and technical requirements apply. Grid operators may control such installations in a grid-oriented manner only on this basis, for example to avert local overload. The smart meter gateway serves as a secured communication path. Switching takes place via a separate control device. The meter does not make the control decision.
The smart metering system must also be distinguished from an energy management system. Such a system optimises, for example, the self-consumption of a PV system, the charging of an electric car or the operation of a home battery. The smart metering system supplies reliable measured values for this and can provide communication paths. It is not the building's optimisation software.
Why smart metering systems matter in the electricity system
Wind and solar power fluctuate with the weather. At the same time, electrification creates new loads in heating and transport. As a result, besides the annual quantity, the load profile also becomes more important. A dynamic electricity tariff presupposes that consumption can be assigned to individual time intervals. Without suitable measurement, a price advantage would be spread out through flat-rate averages. This also concerns flexibility: load shifting has economic value only if it is verifiable and enters billing or balancing. The Bundesnetzagentur points out that installation alone is not enough. The data must also be transmitted reliably. Only then does the basis for time-variable tariffs and more efficient grid control arise.
For grid operators, finer measurement data can help to better understand loads in the low-voltage grid. For a long time, it was hardly known how heavily individual local network transformers are loaded at what time. Smart metering systems do not automatically create complete grid transparency. But they can supply measurement points, especially where many PV systems feed in or many charging points draw power simultaneously. Suppliers and balance responsible parties benefit because they can procure more precisely and allocate deviations more cleanly. The prerequisite is that data quality and market processes can actually process the fine time resolution.
Status of the rollout
As of the reference date of 30 June 2026, metering point operators reported 54,135,202 metering locations to the Bundesnetzagentur. A smart metering system was installed at 3,172,579 of them, which is about 5.9 percent. In the first half of 2026, after a data correction, about 765,000 devices were added. This overall rate refers to all metering points. It is not to be confused with the rate for mandatory installation cases, which is significantly higher. Until now, a target of 20 percent of mandatory cases applied for the end of 2025. From the end of 2026, new period-based rates are decisive. By 2032, the mandatory installation cases are to be largely equipped. The smart meter rollout is thus an ongoing process whose figures change every half year.
Typical misinterpretations
-
Just a reading device: Remote reading saves manual processes. However, the greater significance for the electricity economy lies in time-allocated measurement at millions of decentralised connections.
-
Just an expensive meter replacement: This compares a simple measuring device with a regulated, secured communication infrastructure. A more useful question is which functions would be more expensive, less accurate or not possible at all without this infrastructure. The individual benefit depends on consumption, controllable devices, tariff and grid area.
-
Data protection as a side issue: Fine-grained measured values can allow conclusions about presence and appliance use. For this reason, the law requires protection profiles, Technical Guidelines and certificate-based communication. These requirements are a precondition for the infrastructure to be accepted.
What the term makes visible and what it does not
The term stands for the transition from flat-rate to time-based measurement. The meter is thus no longer just the device that is read once a year. It becomes a regulated access point between connection user, metering point operator, supplier, grid operator and other authorised market roles. Whether an electricity system is flexible, cost-efficient or secure in supply is not explained by the term alone, however. This requires suitable tariffs, clear rules for controllable devices, sufficient grid capacity, reliable data processes and devices that respond to signals. The value of the smart metering system is determined by what is actually implemented with this infrastructure.
Sources
- Messstellenbetriebsgesetz (MsbG) § 2 Begriffsbestimmungen — Bundesministerium der Justiz / gesetze-im-internet.de; unbekannt (konsolidierte Fassung, abgerufen 28.11.2026). § 2 Nr. 7, 11, 12, 15, 19, 20, 21, 24, 27
- Messstellenbetriebsgesetz (MsbG), Gesamttext — Bundesministerium der Justiz / gesetze-im-internet.de; unbekannt (konsolidierte Fassung). § 29 Abs. 1 Nr. 1 und 2; § 30
- § 30 MsbG – Wirtschaftliche Vertretbarkeit; Preisobergrenzen — LexMea (Gesetzestext-Wiedergabe); unbekannt (Import 25.12.2025). § 30 Abs. 2, 3, 6
- Roll-out intelligenter Messsysteme — Bundesnetzagentur; unbekannt (Datenauswertung H1/2026, Stichtag 30.06.2026). Abschnitt Ergebnisse der Datenauswertung H1/2026
- Bundesnetzagentur veröffentlicht halbjährliche Erhebung im Messwesen — Bundesnetzagentur; 2026-09-21. Pressemitteilung, Abschnitte Datenkorrektur, Datenübermittlung, Ausblick
Related glossary entries
- smart meter gateway
- modern metering device
- load profile
- smart meter
- smart grid
- Ferraris meter
- standard load profile
- Metering point operation
- Metering Point Operation Act (MsbG)
- controllable consumption device
- energy management system
- electrification
- dynamic electricity tariff
- flexibility
- smart meter rollout
Edited by eCMS on 28.11.2026 12:01
© 2026 Erik Schmidt. All rights reserved. Quotations with a link to the source are welcome.