← All terms

Glossary · Energy industry & energy transition

Maintenance

Maintenance refers to all technical and administrative actions, as well as management actions, that keep an asset in a functional state during its life cycle or return it to that state after a fault, so that it performs its required function. In the power system, this concerns power plants, substations, transformers, lines, switchgear, protection and control technology, metering technology, battery storage, auxiliary systems and, increasingly, software. Maintenance is not a side task of operations. It is a basic precondition for electrical energy to be generated, transmitted, distributed and used reliably.

The four basic measures

In the German-speaking region, the standard DIN 31051, in conjunction with the European terminology standard DIN EN 13306, divides maintenance into four basic measures. This can be illustrated with the concept of a wear reserve (Abnutzungsvorrat), i.e. the reserve of functional capability that a component gradually consumes through wear.

  • Inspection: Determining and assessing the actual condition, for example by visual inspection, measurement, diagnosis or functional testing, without altering the asset.

  • Servicing: Delaying the depletion of the wear reserve, for example by cleaning, lubricating, readjusting or the scheduled replacement of wear parts.

  • Repair: Restoring the function of a faulty item through physical measures, for example by repairing or replacing defective parts.

  • Improvement: Increasing reliability, maintainability or safety without changing the originally required function. One example is a more robust sensor at a point where faults keep recurring. A modernisation intended mainly to deliver a new function or higher efficiency does not fall under improvement in the narrower sense of the standard, but rather under renewal or investment.

This distinction has practical consequences: a servicing plan, a fault rectification and an improvement involve different costs, responsibilities, risks and time windows. Maintenance is often equated with servicing. This simplification obscures the fact that a large part of reliability results from monitoring, diagnosis, spare-parts strategy, documentation, training and planned intervention logic. The operator must know which components age quickly, which measured values indicate deterioration, what the consequences of a failure would be, and when an intervention is possible without endangering supply.

Strategies in technical operation

Power assets age differently. An overhead line conductor is exposed to different stresses than an underground cable, a transformer differently than a circuit breaker, a wind farm differently than a conventional power plant. Temperature, humidity, switching operations, short-circuit stresses, mechanical loading, corrosion, contamination and the ageing of electronics each have different effects. Various strategies have developed as a result:

  • Corrective maintenance: Repair takes place only after a fault. For non-critical or redundantly designed components, this can make sense. It is risky if a failure has major consequences for supply or if spare parts have long lead times, as is often the case with large power transformers.

  • Preventive maintenance at fixed intervals: Interventions are based on calendar time, operating hours or switching cycles.

  • Condition-based maintenance: Measured values and diagnoses determine the timing. Examples include the analysis of oil and the gases dissolved in it for transformers, partial discharge measurements on cables, thermography, vibration analysis on rotating machines and online monitoring in substations.

  • Risk-based maintenance: The condition is additionally weighted by the importance of the asset to the grid. This approach is a core element of asset management at grid operators.

No strategy is superior for all assets. Fixed intervals can come too early or too late, and condition data can be incomplete or misinterpreted. Maintenance is therefore always also risk management: it links the probability of a failure with its consequences. In the power grid the consequences are significant, because generation and consumption must be balanced continuously, equipment must not exceed its thermal limits, and protection technology must disconnect faults quickly and selectively. A defective component can reduce reserves, change switching states and aggravate congestion. The link to security of supply therefore lies less in individual repairs than in the fact that many assets remain available in a plannable way over long periods.

Planned unavailability and operational security

Maintenance itself creates unavailability. A line, a power plant unit or a transformer that is taken out of service for testing is missing from ongoing operation. This is not a sign of poor supply, but part of safe operational management. The outage must, however, be scheduled so that sufficient reserves remain. Power plant overhauls are therefore often planned for periods of lower demand. In the grid, outages must fit with load flows, feed-in from renewable energies, construction work and the N-1 criterion. This criterion requires that the failure of a single piece of equipment does not lead to impermissible states. During an isolation, it must be checked again with the element already switched off. Isolations therefore reduce the available grid capacity and can trigger redispatch.

In the EU, this coordination is regulated for the transmission grid. The System Operation Guideline (Regulation (EU) 2017/1485) obliges transmission system operators to assess and coordinate the availability plans of relevant grid elements, power generating modules and demand facilities for the following year. Relevant assets are those whose availability affects cross-border operational security. If a combination of planned outages leads to operational security limits being exceeded, the regulation speaks of an incompatibility in outage planning, which must be resolved. Unplanned, fault-related unavailabilities must be reported to the transmission system operator.

Maintenance is also relevant to the market. Under the EU Regulation on Wholesale Energy Market Integrity and Transparency (REMIT, Regulation (EU) No 1227/2011), information on the capacity and use of generation, storage, consumption and transmission facilities can constitute inside information. This includes planned and unplanned unavailabilities. Market participants must publish such information effectively and in a timely manner. A major overhaul is thus not only technical information but, under certain circumstances, also information subject to disclosure.

A common misconception is to view maintenance only as a cost item. Postponed measures can appear cheaper in the short term, but they often increase the risk of an unplanned outage. Such outages are usually more expensive: they occur without a suitable time window, require personnel and material at short notice and can cause consequential damage. The opposite mistake also occurs. Interventions that are too frequent can stress assets, cause new faults through assembly or parameterisation errors and tie up personnel. Good maintenance therefore does not seek the largest number of measures, but a balanced relationship between knowledge of condition, depth of intervention, spare-parts availability and risk.

Legal, economic and institutional context

In Germany, section 11(1) of the Energy Industry Act (Energiewirtschaftsgesetz) obliges operators of energy supply networks to operate, service and, in line with demand, optimise, reinforce and expand a safe, reliable and efficient network on a non-discriminatory basis, insofar as this is economically reasonable. They carry out these tasks on their own responsibility. According to section 11(1a), safe operation also includes adequate protection of the telecommunications and data processing systems used for grid control. The duty to maintain is thus anchored in law. How it is implemented is regulated mainly by technical rules and operational concepts.

Grid operators finance their tasks through grid charges and are subject to regulation with efficiency requirements. This creates a tension between ongoing operating costs, to which maintenance typically belongs, and investments in renewal. An old transformer can continue to be operated through more intensive maintenance. At some point, however, replacement becomes more economical and safer. When that is the case depends on condition, loading, the spare-parts market, consequences of failure and grid planning, that is, on technical service life and equally on economic considerations.

Different incentives apply to power plants and storage. Operators bear the maintenance costs, lose revenue during overhauls and must meet availability commitments arising from contracts or reserve products. Installed capacity says little if an asset cannot be dispatched because of an overhaul, a fault or lack of operational readiness. Availability is therefore the result of a technical preservation process. Several roles are involved: owners decide on investments, operators organise operation and maintenance, grid control centres issue clearances, manufacturers supply maintenance specifications and spare parts, and authorities set safety and documentation obligations. For work on electrical installations, occupational safety and isolation rules also apply, because errors can be life-threatening for personnel.

New requirements through electrification and digitalisation

Heat pumps, electromobility and electric process heat make the economy and households more dependent on grids and equipment. At the same time, the share of decentralised generation, power electronics and storage is growing. This does not automatically make the infrastructure less stable, but it makes it more fine-grained, more data-dependent and more reliant on coordination. Sensors, telecontrol technology and data analytics extend condition monitoring, but create new maintenance objects: communication links, software versions, security certificates, parameterisations and interfaces. A substation can be electrically intact and yet only partly usable if control, communication or IT security fails.

Maintenance thus moves closer to flexibility and system planning. If loads are to be shifted, storage deployed or assets curtailed, the switching and control chains required for this must be tested and reliably controllable. Security of supply therefore arises not through new assets, installed capacity or market rules alone. It also depends on whether the existing infrastructure remains available over the years, whether interventions can be planned, and whether technical risks are identified in good time.

Sources

Related glossary entries

Edited by eCMS on 28.11.2026 12:01

© 2026 Erik Schmidt. All rights reserved. Quotations with a link to the source are welcome.