Glossary · Energy industry & energy transition
Intraday trading
Intraday trading is the short-term trading of electricity for delivery periods of the current or the next delivery day. It begins after the auction of the day-ahead market and ends shortly before physical delivery. Market participants use it to adjust their electricity volumes to expected actual feed-in and offtake. Reasons include new weather forecasts, power plant outages, unplanned changes in consumption, changed schedules of storage facilities or short-term price signals. In the German-Luxembourg bidding zone, continuous intraday trading for the following day opens on the preceding day at 3 p.m.
What is traded is electrical energy for precisely defined delivery intervals. These are mostly quarter-hour or hourly contracts, and in some markets also half-hour contracts. In bids, the quantity is stated as power in megawatts, which applies throughout the whole interval. The energy quantity results from power multiplied by duration: 10 megawatts for a quarter-hour correspond to 2.5 megawatt-hours. This distinction is important. Intraday trading does not balance "electricity" in general, but energy quantities allocated to specific time windows.
Process: continuous trading and intraday auctions
The intraday market has two forms. In continuous trading, participants enter buy and sell orders into an order book. A trade is concluded as soon as two matching orders meet. There is no uniform price determination, so the same delivery period can be traded at different prices depending on the time of trading. In addition, there are Europe-wide coupled intraday auctions with a single price per bidding zone and delivery period. The IDA1 auction closes on the preceding day at 3 p.m., IDA2 on the preceding day at 10 p.m. Both cover the entire delivery day. IDA3 closes on the delivery day at 10 a.m. and relates to the delivery periods from 12 noon to midnight.
Across national borders, continuous trading runs via the European Single Intraday Coupling (SIDC). Exchanges and transmission system operators maintain a shared order book there and link it to the available cross-border transmission capacity. An order from one country can therefore be matched with an order from another country as long as capacity is still available between the two bidding zones. When a trade is concluded, the capacity used is immediately deducted from the available supply.
Different deadlines apply for gate closure. For cross-border trading, gate closure was for a long time 60 minutes before the start of the delivery period. Following the reform of the EU electricity market design, it is to be reduced to at most 30 minutes. ACER adjusted the methodology for this in December 2025. The first borders switched on 14 January 2026. The others follow step by step on the basis of national exemptions; by 2029 the changeover is expected to be completed at most borders. Which deadline applies at a border therefore depends on the border and on the date. Within a bidding zone, trading is usually possible closer to delivery. In Germany, according to the Monopolkommission, this was possible up to five minutes before the start of delivery within a control area and up to 30 minutes between control areas.
Distinction from the day-ahead market, balancing energy (reserve) and imbalance energy
The day-ahead market serves procurement and marketing for the following day. A large part of the dispatch planning of power plants, storage facilities and trading portfolios is based on it. Since delivery day 1 October 2025, the European day-ahead coupling also works with quarter-hours instead of hours. Intraday trading starts after that and corrects positions when the information situation changes. An example: a wind farm operator finds in the morning that the expected feed-in in the afternoon is lower than assumed on the preceding day. It can then buy the missing quantity for the affected quarter-hours, instead of letting the deviation run until settlement.
Balancing energy serves a different purpose and falls under a different responsibility. Intraday trades are market transactions by which participants voluntarily adjust their schedules. Balancing energy is deployed by the transmission system operators to stabilise frequency and the power balance in real time. It therefore belongs to grid operation. Imbalance energy is likewise not a synonym. It arises in settlement when a balancing group actually deviates from its notified schedule. Imbalance energy is then settled for the deviation quantity. The intraday market comes before this in time. With it, such deviations can be avoided or reduced, but it does not replace the reserve needed for secure grid operation.
Why short-term trading is needed
In the power system, generation and consumption must match at every moment, taking storage and exchange with neighbouring countries into account. A schedule that was plausible on the preceding day may no longer fit on the delivery day. With growing shares of wind and solar power, this becomes more important. Weather-dependent generation can be forecast, but not planned precisely. A forecast error generally becomes smaller the closer delivery gets. The intraday market makes this better information tradable. According to ENTSO-E, an integrated intraday market makes it easier to deal with unexpected changes in consumption and with outages, and can reduce the need for reserves.
It does not automatically follow that more renewable energy means more uncertainty. Forecast errors partly offset one another across regions and portfolios. Larger coupled market areas, better data, storage and controllable loads can lower integration costs. Intraday trading does not make deviations invisible. It gives them a price and a place in the market.
Prices, flexibility and quarter-hours
Intraday prices result from short-term supply and short-term demand for individual delivery periods. They can deviate significantly from the day-ahead price. If a power plant unexpectedly fails, demand for replacement quantities rises. If more wind blows than expected, selling pressure arises. With a lot of solar power and low consumption, prices can become very low or negative; in times of scarcity they can rise sharply. In European intraday trading, prices from minus 9,999 to plus 9,999 euros per megawatt-hour are permitted. The smallest quantity step is 0.1 megawatt.
These prices are signals for flexibility. A battery storage system can charge at low prices and discharge at high prices. Electrolysers, large heat pumps in heating networks, cold stores or industrial processes can shift their consumption, to the extent that technology and production allow. Flexible power plants can ramp up or down at short notice if fuel costs, start-up costs and minimum loads fit.
The quarter-hour is more than a detail of settlement. Many deviations arise in short time windows. Photovoltaics changes the residual load particularly in the ramps in the morning and in the evening. Anyone who looks only at hourly averages overlooks such stresses. Quarter-hour products, by contrast, show in which interval energy is scarce or in surplus.
Typical misunderstandings
-
Repair shop: Intraday trading is a regular part of the market organisation and not a stopgap. The day-ahead market provides a central reference, but cannot contain information that only becomes available later.
-
Volatility equals supply risk: High short-term prices can indicate scarcity. On their own, however, they do not show whether sufficient firm capacity, grid capacity and reserve are available and thus whether security of supply is ensured.
-
Responsibility: Balance responsible parties must keep their balancing groups balanced. Intraday trading helps with this, but does not remove this obligation. Anyone who fails to readjust despite new information risks imbalance energy costs. Anyone who trades bears price risks for doing so.
-
Negative prices: Negative electricity prices do not mean that electricity is worthless. They show that additional feed-in in this time window places a burden on the system. Reasons can be technical minimum outputs, support scheme rules, grid congestion or lack of controllability.
Institutional context
Intraday trading is closely linked to balancing group management, schedule notification and market coupling. The closer delivery gets, the more responsibility shifts from trading to grid operation. Gate closure separates voluntary market adjustments from interventions by grid operators. Cross-border trades are only possible as long as transmission capacity is available. The intraday market is therefore not a free-floating financial market. It is tied to bidding zones, grid capacities and schedule processes. It does not reflect congestion within a bidding zone; this is resolved, for example, through redispatch.
Intraday trading is important for the transformation of the power system because it makes the value of short-term adaptability visible in prices. However, it shows only part of the system costs: grid expansion, reserve provision, redispatch and metering and control technology are not fully reflected in it. Properly understood, the term does not mean hectic rework. It refers to the organised correction of schedules in a system that must be balanced in every quarter-hour.
Sources
- Trading Products — EPEX SPOT; unbekannt. Abschnitte Intraday continuous und Intraday auctions
- Single Intraday Coupling (SIDC) — ENTSO-E; unbekannt (Stand der Seite 2026). Abschnitte What is SIDC, How Does SIDC Work, Market Information, Cross-Zonal Gate Closure Times
- ACER Decision No 11/2025 on amendments to the intraday cross zonal gate opening and gate closure times — ACER; 2025-12-19. Entscheidung, Erwägungen zu Art. 8 Abs. 1 Verordnung (EU) 2019/943
- Successful Implementation of 15-Minute Market Time Unit (MTU) in SDAC — EPEX SPOT / SDAC-Parteien; 2025-10-07. Pressemitteilung, erster Absatz
- Competition between electricity exchanges in Germany (Kapitel III) — Monopolkommission; unbekannt. Kapitel III, Einleitung und Abbildung 3.2
Related glossary entries
- day-ahead market
- Balancing energy
- transmission system operators
- balancing group
- schedule
- Imbalance energy
- forecast error
- flexibility
- battery storage system
- residual load
- security of supply
- Negative electricity prices
- redispatch
Edited by eCMS on 28.11.2026 12:01
© 2026 Erik Schmidt. All rights reserved. Quotations with a link to the source are welcome.