Frequency

In an alternating current grid, frequency indicates how many complete oscillations voltage and current go through per second. Its unit is the hertz (Hz), where 1 Hz corresponds to one oscillation per second. For all synchronous areas in Europe, the nominal frequency is legally set at 50 Hz. One period therefore lasts 20 milliseconds. Because the polarity reverses twice within each period, at 50 Hz voltage and current change direction one hundred times per second, not fifty times. The 50 Hz is more than a technical habit. It is a common operating parameter for a large, synchronously coupled interconnected grid that extends from Portugal to Turkey.

The grid frequency results from the interaction of all synchronously coupled generators, loads and grid elements. In an alternating current system, generation and consumption must match at every moment. If more power is drawn than is fed in, the missing energy initially comes from the kinetic energy of rotating machines. These slow down and the frequency falls. If more is fed in than consumed, the machines accelerate and the frequency rises. An illustrative comparison is a bicycle with many riders: if the group pedals harder than the headwind slows it down, it speeds up, otherwise it slows down. Frequency therefore shows very directly whether there is currently a power surplus or a power deficit.

Frequency must be distinguished from electrical power and energy. Power describes how much is generated or consumed at a given moment, for example in kilowatts or megawatts. Energy is the quantity delivered or consumed over a period of time, measured for example in kilowatt hours. Frequency is neither a consumption nor a generation quantity, but a state variable of the synchronous system. It responds to imbalances in instantaneous power, not to the annual total of electricity consumption.

Equally important is the distinction from voltage. Voltage describes the potential difference between two points. In the low-voltage grid it is nominally 230 volts between line conductor and neutral conductor, in the transmission grid it is several hundred kilovolts. Voltage can fluctuate significantly from place to place and depends, among other things, on reactive power, line loading, transformers and local feed-in. Frequency, by contrast, is practically the same throughout the entire synchronous interconnection in steady state. Only immediately after disturbances are there briefly small regional differences and oscillations. A change in frequency therefore affects the entire synchronously coupled grid area.

Frequency as an indicator of balance

Frequency is so informative because a large alternating current grid itself stores hardly any energy. Lines transport power but do not buffer any significant amounts of energy. Feed-in must therefore be continuously adjusted to consumption. For this purpose there are schedules, forecasts, power plant control, storage, flexible loads and balancing energy.

Small frequency deviations are normal, because consumption and feed-in change constantly, for example due to industrial processes, household appliances, gusts of wind, cloud fields or power plant outages. For the Continental Europe synchronous area, the EU Guideline on Electricity Transmission System Operation (Regulation (EU) 2017/1485) sets standard values. These include a standard frequency range of ±50 mHz, i.e. 49.95 to 50.05 Hz, and a maximum steady-state deviation of 200 mHz. Immediately after an incident, the deviation may be at most 800 mHz. The frequency is to be restored within 15 minutes. The regulation also names a target value: at most 15,000 minutes per year outside the standard range. The transmission system operators of a synchronous area can propose other values, so these are standard values and not immutable constants. Other synchronous areas such as the Nordic area or Great Britain operate with different bands.

Frequency control begins with physical inertia. Synchronous machines in coal, gas, hydro or nuclear power plants have large rotating masses. If power is suddenly lacking, these masses release kinetic energy immediately and without any control action. As a result, the frequency falls more slowly, and the control systems gain time. This effect is called instantaneous reserve. It is not a control reserve in the market sense, but a physical property of synchronously coupled machines. Its provision can, however, increasingly be explicitly procured.

Then graduated control reserves take effect. In Europe, the designations of the EU network codes have by now become established:

  • Frequency Containment Reserve (FCR), formerly primary control: It is activated automatically and in a decentralised manner via the locally measured frequency and must be fully delivered within 30 seconds. Its task is to stop the frequency decline or rise and to stabilise the frequency at a deviating level. It does not bring the frequency back to 50 Hz. FCR is provided symmetrically and shared jointly across the whole synchronous area.

  • Automatic Frequency Restoration Reserve (aFRR), formerly secondary control: A central load-frequency controller of the transmission system operator calls it up. The first response occurs after about 30 seconds, and it must be fully delivered after five minutes. It returns the frequency and the power exchange of the control area to the setpoint and replaces the FCR.

  • Manual Frequency Restoration Reserve (mFRR), formerly tertiary control or minute reserve: It is called up in the case of larger or longer-lasting imbalances, in Germany according to current information must be fully delivered within 12.5 minutes, and replaces the aFRR so that the latter becomes available again.

Correction compared with older accounts: Redispatch is not a stage of frequency control. It serves to resolve grid congestion by shifting generation regionally without changing the overall balance. Frequency control is a chain of physical inertia and several control stages that differ in time range, responsibility and purpose.

Why 50 hertz cannot be taken for granted

The target frequency does not have to be reached exactly at all times, because devices, motors, protection systems and power plants are designed for a tolerance range. It becomes critical when the frequency deviates too much or too quickly. Then installations can disconnect automatically, protective functions can trip or new imbalances can arise. For severe underfrequency there is a last emergency measure, automatic frequency-dependent load shedding. Under the EU Network Code on Emergency and Restoration (Regulation (EU) 2017/2196), in Continental Europe it begins at 49.0 Hz at the latest with 5 percent of total load and continues in steps down to 48.0 Hz. What is decisive for stability is therefore not only the size of the deviation, but also its rate of change and duration.

With the expansion of wind and solar energy, the technical basis of frequency control is changing. Many of these installations feed in via inverters and other power electronics and are not electromechanically coupled to the grid frequency like synchronous machines. This does not mean that renewable generators necessarily worsen stability. However, their contributions must be provided and controlled differently. Inverters can respond very quickly. For this, however, they need suitable control, requirements, measured variables and incentives.

Frequency stability is often equated solely with conventional power plants. These used to supply many stabilising properties as a by-product. If they run less often, the need for these properties nevertheless remains. They must be explicitly procured, technically replicated or replaced by other equipment. These include battery storage, grid-forming inverters, flywheels, pumped storage power plants, rotating phase shifters, flexible loads and adapted grid connection rules.

Conventional, grid-following inverters orient themselves to an existing, stable voltage signal and feed in power synchronised to it. Grid-forming inverters, by contrast, can themselves emulate a voltage source with its own frequency and phase angle and thus take over properties that formerly mainly synchronous machines had, for example an inertia-like response. Frequency control thus depends less on the power plant structure and more on the capabilities of individual installations and the rules at their grid connection point.

Misconceptions in the public debate

Frequency is often used as a simple measure of stability. Yet deviations are provided for in normal operation and are continuously corrected. A value of 49.99 Hz lies within the Continental European standard range and does not indicate a collapse. What is relevant are the size, duration and rate of change of the deviation as well as the available countermeasures.

Exchange prices and frequency are also not directly related. High or low prices do not mean a frequency deviation. The electricity market works with schedules and trading periods, whereas frequency arises in the physical instant. However, schedule jumps at hour boundaries or quarter-hour boundaries can cause measurable deterministic frequency deviations. The price shows scarcity or surplus in a market area and a trading period, the frequency the instantaneous physical balance in the synchronous grid.

Security of supply is also often confused with frequency stability. Security of supply means meeting demand even under unfavourable conditions, operating grids reliably, holding reserves and managing disturbances. Frequency stability is only one part of this. A system can have enough energy and power and still be vulnerable due to unsuitable control or too little instantaneous reserve. Conversely, a stable frequency at the moment does not prove that enough firm capacity is available in the long term.

Frequency also does not show where in the grid a bottleneck lies. A transmission grid can be regionally overloaded while the frequency is close to 50 Hz. Bottlenecks concern lines, transformers, power flows and regional feed-in, whereas frequency control concerns the overall balance. Redispatch can therefore be necessary even though the frequency is unremarkable.

Institutions, rules and incentives

Frequency control is also a question of responsibilities. Involved are transmission and distribution system operators, operators of power plants and storage, suppliers, balance responsible parties and regulatory authorities. Balancing groups are supposed to balance feed-in and withdrawal according to schedule. The transmission system operators procure control reserve, in Germany jointly via the platform regelleistung.net, and coordinate interconnected operation. Grid connection rules specify how installations must respond to frequency deviations, for example with a frequency-dependent power reduction in case of overfrequency.

Technical capability alone is not enough. A battery can provide power very quickly if measurement, control, prequalification, remuneration and activation fit together. The German prequalification conditions stipulate, for example, that FCR must be fully delivered within 30 seconds, aFRR within five minutes and mFRR within 12.5 minutes. A flexible industrial plant can relieve the grid if it is allowed to offer its load change reliably and is not deterred from doing so by unsuitable grid fee or market rules.

With increasing electrification, this coordination becomes more important. Heat pumps, electric vehicles, electrolysers and electric industrial processes increase electricity demand and change load profiles. Many of these consumers can be shifted in time or regulated within limits. This flexibility can support frequency control and system operation if it is technically tapped and institutionally integrated.

Frequency is thus a precise term for the instantaneous rhythm and balance of an alternating current grid. It does not measure whether electricity is cheap, whether enough energy is available for the winter or whether a region has sufficient grid capacity. It shows whether feed-in and withdrawal in the synchronous grid currently match and how well the technical and organisational mechanisms manage deviations. At this point physics, control engineering and market design interlock directly.