Glossary · Energy industry & energy transition
Discharge power
Discharge power is the electrical power at which a storage system can release stored energy again. It is stated in watts, kilowatts, megawatts or gigawatts and is an instantaneous quantity. It answers the question of how much electrical power the storage system can provide at a given point in time. For a battery storage system, this usually means the power on the alternating-current side. That is the point where the storage system is connected to a plant, a customer connection or the public power grid. In the German Marktstammdatenregister (market master data register), for example, the maximum discharge power in continuous operation is recorded for battery storage systems as gross power. The usable storage capacity in kilowatt-hours and the associated inverter power are stated separately.
Discharge power is not the same as the amount of stored energy. Energy is measured in kilowatt-hours or megawatt-hours, power in kilowatts or megawatts. A storage system with 10 megawatts of discharge power and 20 megawatt-hours of usable energy can, arithmetically, discharge at full power for two hours. If a storage system has the same amount of energy but only 2 megawatts of discharge power, the energy lasts ten hours. In return, it is much weaker at any single moment. The ratio of usable energy to discharge power is called storage duration. This calculation does not replace checking whether the storage system can actually deliver that power continuously under real conditions and according to its operating rules.
Distinction from capacity, charging power and grid connection
The most important distinction is from storage capacity. Capacity indicates how much energy a storage system can absorb and release. Discharge power indicates the rate at which it can release that energy. In debates about storage, the two quantities are often mixed up. When a "large storage system" is mentioned, it remains unclear, without figures in megawatts and megawatt-hours, whether it offers a lot of power, a long duration or both.
Charging power is also not automatically as large as discharge power. Some storage systems can be charged faster than they can be discharged, or the other way round. For batteries, this depends on the cell type, the battery management, thermal limits, the inverter and the design of the overall system. For a pumped storage plant, too, the power in pumping mode and the power in turbine mode are considered separately. The Marktstammdatenregister records the power consumption in pumping mode separately. For the power system, this difference matters a great deal. A storage system that can absorb electricity quickly helps with surpluses in a different way than one that can release electricity quickly.
Discharge power must also be distinguished from grid connection capacity. A battery storage system can internally deliver a certain power. At the grid connection point, however, it may feed in less if the connection agreement, transformer, inverter or protection equipment limit it. The reverse case also occurs. An entry in the Marktstammdatenregister shows, for example, a DC-coupled home storage system with 3.33 kilowatts of discharge power in continuous operation on an inverter rated at 7 kilowatts. There, the battery is the limiting factor, not the inverter. For the effect on the grid, the usable discharge power at the point of transfer is therefore usually what counts. The theoretical capability of individual cells, modules or inverters is not sufficient as a measure.
Technical determining factors
For battery storage systems, the ratio of power to capacity is often described by the C-rate. Strictly speaking, the C-rate relates the discharge current to the nominal capacity in ampere-hours. In practice, however, it is often also applied to power and energy. At 1C, the battery would arithmetically be fully discharged in one hour, at 2C in half an hour and at 0.5C in two hours. A large battery storage system with 12.5 megawatts of discharge power and around 10.7 megawatt-hours of usable capacity, as recorded in the Marktstammdatenregister, is thus at slightly more than 1C. At full power it is therefore empty in less than an hour. The C-rate cannot be chosen freely. It results from cell chemistry, cooling, targeted service life and safety requirements.
Discharge power also depends on the state of charge. Many batteries can achieve higher power in the middle charge range than shortly before full discharge or full charge. Temperature also plays a role. Cold can reduce the available power, while high temperatures can trigger protective functions or accelerate ageing. The battery management system throttles the discharge power when cell voltages, temperatures or the ageing state reach certain thresholds.
For any statement about discharge power, it must be clear whether it refers to continuous power or to short-term peak power. A battery can deliver more power for seconds or minutes than over a longer time. The Marktstammdatenregister expressly requires the power in continuous operation and not the short-term maximum power. For frequency support, a very short, high power can be valuable. For covering an evening load peak, by contrast, what counts is the power that is reliably available over half an hour, two hours or longer. A megawatt figure without a time reference and operating condition can therefore be misleading.
The difference between the direct-current side and the alternating-current side is also important. Battery cells deliver direct current, while the power grid operates with alternating current. The inverter determines how much power arrives on the alternating-current side. Losses in the inverter, in cables, in transformers and in auxiliary systems such as air conditioning reduce the usable output. For market participation, grid connection and balancing, the alternating-current power at the point of transfer is usually what counts.
Why discharge power matters in the power system
Discharge power determines which tasks a storage system can take on in the power system. Anyone who wants to shift energy over several hours mainly needs capacity. In critical moments, by contrast, the available power is what counts. If demand is high, there is little wind and solar power, or power plants fail, a storage system can help only to the extent that its discharge power can actually be called upon.
This concerns security of supply. A storage system with a lot of energy but low discharge power can provide support for a long time. In a tight hour, however, it does not replace large firm capacity. A storage system with high discharge power and short duration can smooth a peak, but cannot bridge a multi-day Dunkelflaute (prolonged period of low wind and solar output). In capacity analyses, grid planning and flexibility assessments, power, duration, availability and dispatch rules must therefore be considered together.
Discharge power is also central to the integration of wind and solar power. Photovoltaics often generates a lot of power at midday, while demand in many grids rises in the evening. Battery storage systems can charge at midday and discharge in the evening. Whether they noticeably reduce the evening residual load depends on their discharge power and their amount of energy. A storage system with a lot of energy but weak discharge changes the load profile only slightly. A storage system with high power but short duration can cushion steep ramps, but is empty afterwards.
In grid operation, discharge power plays a different role than capacity. Storage systems can reduce local peaks, relieve grid equipment, support voltage or provide system services. To do so, they must deliver a certain power at the right time and in the right place. A storage system behind a grid bottleneck does not automatically help on the other side of the bottleneck. Location, grid connection point and controllability help decide whether discharge power actually helps the grid or only appears in the market in accounting terms.
Market, rules and available power
Usable discharge power does not result from technology alone. Market rules and requirements determine when a storage system may discharge, which revenues are possible and which obligations come with providing the service. A storage system can exploit price differences on the electricity market through arbitrage, offer balancing power, optimise grid charges or work in industrial load management. Each of these applications places different demands on response time, duration, metering, prequalification and availability.
This is particularly clear with balancing power. In the continental European synchronous grid, under EU Regulation 2017/1485, primary control power (FCR) must be fully available no later than 30 seconds after a frequency deviation of 200 millihertz or more. Under the prequalification conditions of the German transmission system operators (version of 5 July 2024), the power offered for secondary control power (aFRR) must be available within five minutes. For storage systems with limited energy reserves, Article 156 of the Regulation further provides that full FCR can, as a rule, be delivered continuously for at least 15 minutes. The transmission system operators may set a period between 15 and 30 minutes. In Germany, the Bundesnetzagentur replaced the previously applicable 30 minutes with a minimum delivery period of 15 minutes in 2019. The German prequalification conditions accordingly set the minimum energy capacity of a storage system for FCR and FRR at 15 minutes of the prequalified power. A battery storage system can therefore not market its entire technical discharge power as balancing power. The marketable power also depends on energy content and state-of-charge management.
For arbitrage on the day-ahead or intraday market, what counts is whether charging and discharging fit the prices. In addition, losses, charges and levies must make the operation economically viable. In peak shaving, discharge power reduces the power peaks of a consumer. What counts here is not the average amount of electricity but the highest measured power value in a billing period. For customers with demand metering, it is often determined as an average over a quarter of an hour. The storage system must therefore discharge with sufficient power for as long as the peak lasts.
The same technical discharge power can therefore be worth very different amounts depending on the set of rules. A storage system can be technically flexible and yet be held back by connection conditions, metering concepts, double-levied charges or missing market products. Conversely, a market incentive can steer storage systems to act in a commercially sensible way while exacerbating local grid problems. Conflicts arise where technical possibility, market rule and grid need do not match.
Typical misunderstandings
-
Assessment by a single figure: The statement "100 megawatt storage" says nothing about whether the storage system can deliver for a quarter of an hour, two hours or eight hours. "400 megawatt-hour storage" says nothing about whether the energy can be called upon strongly enough in a critical hour. For statements in energy economics, power and amount of energy always belong together.
-
Installed discharge power equals firm capacity: Installed power describes what a plant can deliver under defined conditions. Firm capacity asks which contribution is available with high probability in scarcity situations. For storage systems, this depends on the state of charge before the scarcity, on previous market dispatch, on forecasts and dispatch strategies, and on regulatory obligations. If a storage system discharged for economic reasons shortly before a shortage situation, it is only of limited availability afterwards, unless a rule safeguards its state of charge.
-
High discharge power solves energy scarcity: Power helps with high demand or rapid changes. If generation is lacking over a longer period, the amount of stored energy becomes the limit. Storage systems with high discharge power therefore complement other options such as generation, load shifting, grid expansion and long-term storage, but do not replace them.
Connection with flexibility and system costs
Discharge power is a key quantity for flexibility. It describes how quickly and to what extent stored energy becomes available as electrical power. Flexibility, however, encompasses more than storage. Controllable loads, power plants, electrolysers, heat pumps, electric vehicles, grids and market processes can also act flexibly. The discharge power of a storage system is a concrete technical capability within this larger interplay.
For system costs, the distinction between power and energy is particularly important. A storage system with high discharge power needs powerful inverters, transformers, protection equipment and often more elaborate cooling. A storage system with long duration needs more storage medium, in the case of batteries more cells. Both designs cost different amounts and bring different benefits. Anyone who compares storage systems only by cost per kilowatt-hour overlooks the cost of power. Anyone who looks only at euros per kilowatt overlooks the duration and thus the contribution to energy shifting.
Discharge power shows what instantaneous effect a storage system can have in the power system. Whether this contribution is sufficient, economical or serves the system, it does not explain on its own. For that, storage capacity, charging power, efficiency, location, availability, control, market rules and grid conditions must also be considered. Used precisely, the term does not denote a general storage quality. It describes the ability to convert stored energy back into electrical power at a given point in time and at a given strength.
Sources
- Verordnung (EU) 2017/1485 der Kommission vom 2. August 2017 zur Festlegung einer Leitlinie für den Übertragungsnetzbetrieb — Europäische Union (EUR-Lex); 2017-08-02. Anhang zu den FCR-Mindestanforderungen (Zeit bis zur vollständigen FCR-Aktivierung)
- Art. 156 Regulation (EU) 2017/1485 – FCR provision — Lexparency (Wiedergabe des Verordnungstexts); unbekannt. Artikel 156 Absätze 8 und 9
- Präqualifikationsverfahren für Regelreserveanbieter (FCR, aFRR, mFRR) — Deutsche Übertragungsnetzbetreiber (regelleistung.net); 2024-07-05. Abschnitt zur Untergrenze des Arbeitsvermögens relativ zur PQ-Leistung; Vermarktbare Leistung
- Beschluss BK6-17-234 vom 2. Mai 2019 (Mindesterbringungszeitraum FCR für begrenzte Energiespeicher) — Bundesnetzagentur; 2019-05-02. Tenor und Begründung zum Mindesterbringungszeitraum
- Marktstammdatenregister – öffentliche Einheitenansicht „Stromspeicher PV“ (SEE941963400080) — Bundesnetzagentur (Marktstammdatenregister); 2020-11-28. Abschnitte Leistung, Batterie und Angaben zum Stromspeicher
Related glossary entries
- storage duration
- storage capacity
- Charging power
- pumped storage plant
- grid connection point
- C-rate
- battery management system
- inverter
- power
- security of supply
- Dunkelflaute (prolonged period of low wind and solar output)
- residual load
- arbitrage
- balancing power
- day-ahead
- peak shaving
- Firm capacity
- flexibility
- system costs